Product Description
Product Description
1nuo /YINUO Pipe Fittings Standard Grooved Pipe Fittings grooved coupling
production process
A rough castings of grooved fittings will be processed and produced by electric-furnice smelting,on-line monitoring and control and automatic molding methods.
Product Parameters
1. High Pressure Coupling Specification:
Size | Pipe O.D | Working Pressure | Bolt Size |
mm/in | PSI/MPa | No.-Size mm | |
25 1 |
33.7 1.327 |
750 5.17 |
2-M10*45 |
32 1¼ |
42.4 1.669 |
750 5.17 |
2-M10*45 |
40 1 1/2 |
48.3 1.900 |
750 5.17 |
2-M10*45 |
50 2 |
60.3 2.375 |
750 5.17 |
2-M10*55 |
65 2 1/2 |
73 2.875 |
750 5.17 |
2-M10*55 |
65 3OD |
76.1 3.000 |
300 2.07 |
2-M10*55 |
80 3 |
88.9 3.500 |
750 5.17 |
2-M10*60 |
100 4 |
114.3 4.500 |
750 5.17 |
2-M10*65 |
125 5.5OD |
139.7 5.500 |
750 5.17 |
2-M10*75 |
150 6 OD |
165.1 6.500 |
750 5.17 |
2-M10*75 |
150 6 |
168.3 6.625 |
750 5.17 |
2-M10*75 |
200 8 |
219.1 8.625 |
750 5.17 |
2-M10*100 |
250 10 |
273.0 10.748 |
750 5.17 |
2-M10*130 |
300 12 |
323.9 12.752 |
750 5.17 |
2-M10*130 |
Product Details
Material | Ductile Iron-ASTM A536 |
Thread Standard | BSPT/ BSPP/ NPT |
Bolt and Nut | Cold Heading Steel- Gold color |
Pressure | 750 CHINAMFG – 5.17Mpa |
Finish | Epoxy/ Painted / Galvanized |
Color | Ral 3000 Red / Orange/ Blue/ White |
Brand | 1NUO |
Package | Cartons with Pallet / Wooden Case |
Delivery Time | 20-40 days as per ever order |
Capacity | Four Automatic Vertical Production Lines |
Application | 1. fire fighting& fire sprinkler system for commercial and civil fire protection construction, such as water supplying, gas supplying, air-conditioning etc. |
2. Industrial pipeline system in shipping, mine, oil field, cement, mine piping , chemical plant etc. | |
3. Ordinary piping delivery in sewage treatment, Subway station, airport etc. |
Gasket:
Gasket | Material | Temperature Range | Recommendations |
E | EPDM | -34ºC~ +110ºC | Recommended for hot water, dilute acid, oil-free gas and other chemicals(except for hydrocarbon ) within the specified temperature range. Not recommended for petroleum and hydrocarbon. |
D | NBR | -29ºC~ +82ºC | Recommended for petroleum products, gas with oil vapors, mineral oil and vegetable oil. Not recommended for high temperature materials. |
S | Silicon Rubber | -40ºC~ +177ºC | Recommended for high temperature and dry air, and some high temperature chemicals. |
Certifications
FM Approved&UL Listed&CE Certificate
Packaging & Shipping
To better ensure the safety of your goods, professional, environmentally friendly, convenient and efficient packaging services will be provided.
Company Profile
HangZhou CHINAMFG has strong technical strength and possesses the world’s first-class equipment and technology, as well as perfect testing methods. All rough castings of grooved fittings will be processed and produced by electric-furnace smelting, on-line monitoring and control and automatic molding methods. Now our facilities include 11 medium frequency furnace, 4 advanced vertical parting molding lines and 3 painting lines. Every customer’s requirements can be satisfied by customized services.
Yinuo’s ductile iron grooved fittings have successively passed the China national type test, ISO 9001 and FM&UL approvals etc. Our products are underwritten by China Ping An Insurance(Group) Co.,Ltd. The grooved pipe fittings are widely used in fire fighting, air-conditioning, water supply, sewage, cement, low-pressure steaming, mine piping and ordinary piping delivery.
ø Corporate Vision: Where there is pipes, there is YINUO.
ø Corporate Mission: Connecting pipeline around the world, benefiting homes in every building.
ø Competitive Strategy: To supply market with perfect products, to win customers with excellent service.
ø Core Value: Pragmatic honesty, quality first, continuous innovation and CHINAMFG cooperation.
ø Quality Value: We survive with quality and develop by technology.
Range of products
Rigid coupling, Flexible coupling, 90° Elbow, 45° Elbow, 22.5° Elbow, 11.25° Elbow, Tee, Reducing Tee(Grooved/Threaded), Cross, Reducing Cross(Grooved/Threaded), Mechnical Tee(Grooved/Threaded), Mechnical Cross(Grooved/Threaded), U-bolted Mechnical Tee, Reducer(Grooved/Threaded), Grooved Eccentric Reducer, Grooved Split Flange, Grooved Adaptor Flange, Cap.
Application: As 1 of the most popular fittings in fire fighting systems, the grooved pipe fittings are widely used in fire fighting, air-conditioning, water supply, sewage, cement, oil&gas pipeline, mine piping and ordinary piping delivery. CHINAMFG is spreading all over the world and winning the appreciations from users at home and abroad.
FAQ
Q1. Are you manufactrer?
A: Yes, we are manufacturing&trading combo.
Q2. What are your terms of delivery?
A: EXW, FOB, CFR, CIF.
Q3. What is your delivery time?
A: The time of delivery is around 15-20 days, depending on order quantity.
Q4: Can you provide us with some samples for testing?
A: Of course, we can offer you samples. The sample is free, you only need to bear the freight.
Q5. What is your payment terms?
A: We accept 30% T/T in advance, 70% in the period of shipment or L/C at sight.
Q6. Could you specially design and produce for clients?
A: Sure, we have all kinds of professional engineers.We can design and produce special products according to customers’ request. Such as: special size, special control, OEM, etc.
/* January 22, 2571 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
How do you install and align a flexible coupling properly to ensure optimal performance?
Proper installation and alignment of a flexible coupling are essential to ensure its optimal performance and longevity. Incorrect installation can lead to premature wear, increased vibrations, and potential equipment failure. Below are the steps to install and align a flexible coupling properly:
1. Pre-Installation Inspection:
Before installation, inspect the flexible coupling and its components for any visible damage or defects. Check that the coupling’s size and specifications match the application requirements. Ensure that the shafts and equipment connected to the coupling are clean and free from debris.
2. Shaft Preparation:
Prepare the shafts by removing any oil, grease, or contaminants from the surfaces that will come into contact with the coupling. Ensure that the shaft ends are smooth and free from burrs that could affect the fit of the coupling.
3. Coupling Hub Installation:
Slide the coupling hubs onto the shafts, ensuring they are positioned securely and evenly on each shaft. Use a lubricant recommended by the manufacturer to facilitate the installation and ensure a proper fit.
4. Alignment:
Proper alignment is critical for the performance and longevity of the flexible coupling. Align the shafts by checking both angular and parallel misalignment. Utilize precision alignment tools, such as dial indicators or laser alignment systems, to achieve accurate alignment. Follow the manufacturer’s alignment specifications and tolerance limits.
5. Tightening Fasteners:
Once the shafts are properly aligned, tighten the coupling’s fasteners to the manufacturer’s recommended torque values. Gradually tighten the fasteners in a cross pattern to ensure even distribution of the load on the coupling hubs. Avoid over-tightening, as it may cause distortion or damage to the coupling.
6. Run-Out Check:
After installation, perform a run-out check to verify that the coupling’s rotating components are balanced and aligned. Excessive run-out can lead to vibrations and reduce the coupling’s performance. If significant run-out is detected, recheck the alignment and address any issues that may be causing it.
7. Lubrication:
Ensure that the flexible coupling is adequately lubricated, following the manufacturer’s recommendations. Proper lubrication reduces friction and wear, enhancing the coupling’s efficiency and reliability.
8. Periodic Inspection and Maintenance:
Regularly inspect the flexible coupling for signs of wear, misalignment, or damage. Address any issues promptly to prevent further problems. Depending on the coupling type and application, scheduled maintenance may include re-greasing, re-alignment, or replacing worn components.
Summary:
Proper installation and alignment are crucial for ensuring the optimal performance and longevity of a flexible coupling. Following the manufacturer’s guidelines, inspecting the components, achieving accurate alignment, and using the appropriate lubrication are key steps in the installation process. Regular inspection and maintenance help to identify and address potential issues, ensuring the coupling continues to operate smoothly and efficiently in the mechanical system.
What are the differences between single and double flexible coupling designs?
Single and double flexible couplings are two common designs used for power transmission in various mechanical systems. Here are the main differences between the two:
- Design: The primary difference lies in their configuration. A single flexible coupling consists of one flexible element connecting two shafts, while a double flexible coupling, also known as a two-piece flexible coupling, uses two flexible elements with an intermediate shaft in between. The double flexible coupling resembles two single couplings connected in series.
- Torsional Flexibility: Single flexible couplings typically provide greater torsional flexibility than double flexible couplings. The presence of an intermediate shaft in the double coupling design adds some rigidity and reduces the overall torsional flexibility of the system.
- Compensation of Misalignment: Both single and double flexible couplings can compensate for angular and parallel misalignment between shafts. However, due to its additional flexible element, the double flexible coupling may have slightly better misalignment compensation capabilities.
- Length and Space: Single flexible couplings are generally shorter in length compared to double flexible couplings. The double flexible coupling’s design requires additional space to accommodate the intermediate shaft, making it longer than the single coupling.
- Shaft Separation: Single flexible couplings connect the two shafts directly without any intermediate components, while the double flexible coupling separates the shafts using an intermediate shaft. This shaft separation in the double design can be advantageous in certain applications.
- Stiffness: The double flexible coupling tends to be slightly stiffer than the single flexible coupling due to the presence of the intermediate shaft, which may affect its ability to absorb vibrations and shock loads.
- Application: Single flexible couplings are commonly used in various applications, including pumps, compressors, fans, and general power transmission systems. Double flexible couplings are often preferred in applications where a higher level of torsional stiffness is required, such as certain industrial machinery.
Both single and double flexible coupling designs have their advantages and are suitable for different types of machinery and power transmission requirements. The choice between the two depends on factors such as the specific application, the level of misalignment compensation needed, the available space, and the desired torsional flexibility for the system.
Can flexible couplings be used in corrosive or harsh environments?
Yes, flexible couplings can be designed and selected to be used in corrosive or harsh environments. The choice of materials and coatings plays a crucial role in ensuring the coupling’s durability and performance under challenging conditions.
Corrosion-Resistant Materials:
In corrosive environments, it is essential to use materials that can withstand chemical attacks and oxidation. Stainless steel, specifically grades like 316 or 17-4 PH, is commonly chosen for flexible couplings in such situations. Stainless steel offers excellent corrosion resistance, making it suitable for applications where the coupling may come into contact with corrosive substances or moisture.
Special Coatings:
For certain harsh environments, coupling manufacturers may apply special coatings to enhance the coupling’s corrosion resistance. Examples of coatings include zinc plating, nickel plating, or epoxy coatings. These coatings provide an additional layer of protection against corrosive agents and help extend the coupling’s lifespan.
Sealed Designs:
In environments where the coupling is exposed to contaminants like dust, dirt, or moisture, sealed designs are preferred. Sealed flexible couplings prevent these substances from entering the coupling’s internal components, thus reducing the risk of corrosion and wear. The sealed design also helps to maintain the coupling’s performance over time in challenging conditions.
High-Temperature Applications:
For harsh environments with high temperatures, flexible couplings made from high-temperature resistant materials, such as certain heat-resistant stainless steels or superalloys, can be used. These materials retain their mechanical properties and corrosion resistance even at elevated temperatures.
Chemical Resistance:
For applications where the coupling might encounter chemicals or solvents, it is essential to select a coupling material that is chemically resistant. This prevents degradation and ensures the coupling’s integrity in such environments.
Specialized Designs:
In some cases, where the environment is exceptionally harsh or unique, custom-designed flexible couplings may be necessary. Engineering a coupling to meet the specific demands of the environment ensures optimal performance and reliability.
Consultation with Manufacturers:
When considering flexible couplings for corrosive or harsh environments, it is advisable to consult with coupling manufacturers or engineering experts. They can provide valuable insights and recommend suitable materials, coatings, and designs based on the specific operating conditions.
Summary:
Flexible couplings can indeed be used in corrosive or harsh environments, provided the appropriate materials, coatings, and designs are chosen. Stainless steel, sealed designs, and special coatings are some of the solutions that enhance the coupling’s corrosion resistance and performance. It is essential to consider the specific environment and application requirements when selecting a flexible coupling to ensure optimal functionality and durability in challenging conditions.
editor by CX 2024-04-19